HEINE OMEGA 500 Binocular Indirect Ophthalmoscope

Quality with XHL Xenon-Halogen lamp illumination


Unique “Synchronized Adjustment of Convergence and Parallax” for high quality, stereoscopic fundus images through any pupil size.

More

Unique Synchronized Adjustment of Convergence and Parallax for high quality, stereoscopic fundus images through any pupil size. Precise selection of 
the observation and illumination optics for small pupils down to 1.0 mm.

Excellent optical performance due to the multi-coated illumination system. Exact vertical alignment of the illumination with the observation path further minimising the reflections.

Due to the mounting of the optics on an aluminum frame, the OMEGA 500 is solid, long lasting, and is guaranteed to be dustproof.

The HC 50L Headband Rheostat controls the LED illumination as well as the XHL Xenon-Halogen illumination.

Configurations

Catalogue Number: C-004.33.541

Further articles / Accessories HEINE OMEGA 500 Binocular Indirect Ophthalmoscope


HEINE OMEGA 500 Breath Shield – 1x Breath Shield + 1x mounting clip
HEINE OMEGA 500 Breath Shield – 1x Breath Shield + 1x mounting clip

Breath Shield for direct attachment to the ophthalmoscope – for a clear view and comfortable working. 1x Breath Shield, 1x mounting clip Cleaning and disinfection instructions

C-000.33.016
HEINE OMEGA 500 Breath Shield – 3x Breath Shield + 1x mounting clip
HEINE OMEGA 500 Breath Shield – 3x Breath Shield + 1x mounting clip

Breath Shield for direct attachment to the ophthalmoscope – for a clear view and comfortable working. 3x Breath Shield, 1x mounting clip Cleaning and disinfection instructions

C-000.33.017
Upgrade-Kit OMEGA500
Upgrade-Kit OMEGA500

with LED module and HC 50 L

X-008.16.325
Hard case for Indirect Ophthalmoscope Sets C-283 and C-284 - 470mm x 400mm x 190mm
Hard case for Indirect Ophthalmoscope Sets C-283 and C-284 - 470mm x 400mm x 190mm

Hard case for indirect ophthalmology sets C-283 and C-284

C-079.00.000
Combi-case for Indirect Ophthalmoscope Sets C-283 and C-284 - 432mm x 330mm x 197mm
Combi-case for Indirect Ophthalmoscope Sets C-283 and C-284 - 432mm x 330mm x 197mm

Combi-case for Indirect Ophthalmoscope Sets C-283 and C-284

C-079.03.000
Fundus-Charts
Fundus-Charts

with 50 pcs.

C-000.33.208
OMEGA 500 5W - Standard equipment
OMEGA 500 5W - Standard equipment

XHL Xenon Halogen spare bulb 6 V, 5 W, standard

X-004.88.111
Upgrade-Kit OMEGA500
Upgrade-Kit OMEGA500

LED-module

X-008.87.200
Teaching Mirror
Teaching Mirror

for OMEGA500 Ophthalmoscope

C-000.33.209
Scleral-Depressor small
Scleral-Depressor small

autoclavable

C-000.17.301
Ophthalmoscopy Lens with case
Ophthalmoscopy Lens with case

A.R. 20 D, 50 mm dia.

C-000.17.228
Ophthalmoscopy Lens with case
Ophthalmoscopy Lens with case

A.R. 30 D, 46 mm dia.

C-000.17.231
Scleral-Depressor large
Scleral-Depressor large

autoclavable

C-000.17.300
Ophthalmoscopy Lens with case
Ophthalmoscopy Lens with case

A.R. 16 D, 54 mm dia.

C-000.17.225

FAQ - Frequently Asked Questions


Which power source is compatible with my HEINE OMEGA500?

The HEINE OMEGA 500 can be used with the belt-worn HEINE mPack (8.5 hours opeating time) or with the cable-free HEINE mPack UNPLUGGED (3.5 hours operating time).


 

Can I upgrade from an XHL to an LED version?

Yes, the OMEGA500 can be easily and quickly converted with the help of an upgrade kit. The upgrade kit includes the LED unit plus the HC50 L Rheostat.

 

What does the HEINE HC50 L Headband Rheostat do?

The Rheostat can be conveniently mounted on the left- or right-hand side of the headband and controls LED or XHL illumination. Light-intensity can be precisely adjusted – especially in the low-light intensity range. It also operates as an on/off switch.

 

The HEINE OMEGA500 is marketed as dust proof. Why do I still see dust when looking through the front glass of the indirect ophthalmoscope?

The term dust proof means that the instrument is protected against the infiltration of dust. The instruments have no open and unprotected windows. Nevertheless, in the unlikely case that some dust particles get encased inside the instrument in a heavy use environment, the product can be serviced by HEINE. Microparticles that can be seen through the instrument are normal and don’ t obstruct examination.

 

How do I change the light source in my HEINE OMEGA500?

First allow the instrument to cool down. Disconnect the instrument from the power source. Unscrew the control so that the optics unit is free to move. Slide the bulb cover upwards. Do not pull on the cord. Swivel the optics unit to enable the bulb to be pulled out of the bulbholder. Clean the glass dome of the new bulb carefully with a soft cloth. Insert the new bulb so that the locating pin on the bulb body fits into the guide in the bulbholder. Re-fit the bulb cover into the optics unit and slide the bulb cover back down into position.

Show all FAQs

These HEINE products could also be interesting for you


HEINE ML4 LED HeadLight with HR / HRP Optics
HEINE ML4 LED HeadLight with HR / HRP Optics
HEINE BETA 200 LED Retinoscope
HEINE BETA 200 LED Retinoscope
HEINE LAMBDA 100 Retinometer
HEINE LAMBDA 100 Retinometer
HEINE BETA 200 LED Ophthalmoscope
HEINE BETA 200 LED Ophthalmoscope
HEINE BETA 200S LED Ophthalmoscope
HEINE BETA 200S LED Ophthalmoscope

Find­ a­ distributor

Are you interested in one of our products?
Find a distributor near you quickly and easily.


  • Algeria
  • Argentina
  • Armenia
  • Australia
  • Austria
  • Azerbaijan
  • Bahrain
  • Bangladesh
  • Belarus
  • Belgium
  • Benin
  • Bolivia
  • Bosnia & Herzegovina
  • Botswana
  • Brazil
  • Brunei
  • Bulgaria
  • Burkina Faso
  • Cambodia
  • Cameroon
  • Canada / Alberta
  • Canada / British Columbia
  • Canada / Manitoba
  • Canada / Maritimes
  • Canada / Nova Scotia
  • Canada / Ontario
  • Canada / Quebec
  • Canada / Saskatchewan
  • Chile
  • China
  • Colombia
  • Costa Rica
  • Croatia
  • Cyprus
  • Czechia
  • Côte d’Ivoire
  • Denmark
  • Dominican Republic
  • Ecuador
  • Egypt
  • Estonia
  • Finland
  • France
  • Gabon
  • Georgia
  • Germany
  • Greece
  • Guatemala
  • Honduras
  • Hong Kong SAR China
  • Hungary
  • Iceland
  • India
  • Indonesia
  • Iran
  • Iraq
  • Ireland
  • Israel
  • Italy
  • Japan
  • Jordan
  • Kazakhstan
  • Kenya
  • Kuwait
  • Kyrgyzstan
  • Latvia
  • Lebanon
  • Lithuania
  • Luxembourg
  • Malawi
  • Malaysia
  • Maldives
  • Malta
  • Mauritania
  • Mexico
  • Moldova
  • Mongolia
  • Morocco
  • Mozambique
  • Nederland
  • Nepal
  • Netherlands
  • New Caledonia
  • New Zealand
  • Nicaragua
  • Nigeria
  • Norway
  • Oman
  • Pakistan
  • Panama
  • Papua New Guinea
  • Paraguay
  • Peru
  • Philippines
  • Poland
  • Portugal
  • Qatar
  • Romania
  • Russia
  • Saudi Arabia
  • Serbia and Montenegro
  • Singapore
  • Slovakia
  • Slovenia
  • South Africa
  • South Korea
  • Spain
  • Sri Lanka
  • Sudan
  • Suriname
  • Sweden
  • Switzerland
  • Syria
  • Taiwan
  • Tajikistan
  • Tanzania
  • Thailand
  • Trinidad & Tobago
  • Tunisia
  • Turkey
  • Turkmenistan
  • US-
  • US-IA-US-MS
  • US-RT
  • Uganda
  • Ukraine
  • United Arab Emirates
  • United Kingdom
  • United States
  • United States / Alabama
  • United States / Alaska
  • United States / American Samoa
  • United States / Arizona
  • United States / Arkansas
  • United States / California
  • United States / Colorado
  • United States / Connecticut
  • United States / Delaware
  • United States / District of Columbia
  • United States / Florida
  • United States / Georgia
  • United States / Guam
  • United States / Hawaii
  • United States / Idaho
  • United States / Illinois
  • United States / Indiana
  • United States / Iowa
  • United States / Kansas
  • United States / Kentucky
  • United States / Louisiana
  • United States / Maine
  • United States / Maryland
  • United States / Massachusetts
  • United States / Michigan
  • United States / Minnesota
  • United States / Mississippi
  • United States / Missouri
  • United States / Montana
  • United States / Nebraska
  • United States / Nevada
  • United States / New Hampshire
  • United States / New Jersey
  • United States / New Mexico
  • United States / New York
  • United States / North Carolina
  • United States / North Dakota
  • United States / Northern Mariana Islands
  • United States / Ohio
  • United States / Oklahoma
  • United States / Oregon
  • United States / Pennsylvania
  • United States / Puerto Rico
  • United States / Rhode Island
  • United States / South Carolina
  • United States / South Dakota
  • United States / Tennessee
  • United States / Texas
  • United States / United States Minor Outlying Islands
  • United States / Utah
  • United States / Vermont
  • United States / Virgin Islands, U.S.
  • United States / Virginia
  • United States / Washington
  • United States / West Virginia
  • United States / Wisconsin
  • United States / Wyoming
  • Uruguay
  • Venezuela
  • Vietnam
  • Yemen
  • Zimbabwe
HEINE Quality Made In Germany

As a global leader in the manufacture of primary diagnostic instruments with over 500 employees, HEINE Optotechnik has been a 100 % family owned and managed company for more than 70 years. We continue to develop and manufacture HEINE instruments at our facilities in Germany, where we combine decades-long experience and craftsmanship with the most modern manufacturing technologies.

Quality Made in Germany